Exfo CableSHARK P3 VF/DSL Cable Qualifier Manual de usuario Pagina 281

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 321
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 280
CableSHARK P3 User Guide
269
Accuracy: ±2dB
Return Loss Test (Plot with cursor and zoom)
Range: 0 to 60 dB
Resolution: 0.1 dB
Accuracy: +/- 1 dB from 0 to 40 dB
Horizontal scale: 17 kHz to 2.2 MHz
Vertical scale: 0 to 60 dB
RFL
Resistive Fault Location. Detects faults such as shorts, grounds, and battery crosses.
Displays total loop resistance, resistance to fault & resistance from fault to strap and
equivalent distances.
Fault detection: 0 to 20 M, resolution 3 significant digits
Loop resistance: 7 k maximum
Wire gauges: 0.4, 0.5, 0.6 or 0.8 mm (19, 22, 24, 26 AWG)
Cable temperature range: -40ºF to +140ºF (-40ºC to +60ºC)
Multiple cable sections: 5 (includes gauge and temperature setting)
Fault location: Total resistance, near-end to fault resistance, fault to strap resistance (4 significant
digits)
Total length, distance to fault, distance from fault to strap (1 ft (3 m) resolution
Accuracy: 0.1% ±1 LSB for loop resistance of 0 to 99.99
0.2% ±1 LSB for loop resistance of 100 - 999.99
1% ± 1LSB for loop resistance of 1k – 7k
Ground Resistance
Detects CO voice switch line cards with constant voltage source, constant current source or grounded
balanced source.
Range: 0 to 500
Resolution: 1
Accuracy: ±3 ±1% of reading
Vista de pagina 280