CableSHARK P3 User Guide
169
MAIN
MENU
EF
CHG
VIEW
DETAIL
SAVE /
UPLOAD
DMM
Load Coil
Length(TDR)
Longitudinal Balance
Balance at 1kHz
Capacitance Imbalance
SHDSL Data Rate
Disturber ID =
2312 kbps Passed
undetermined
Passed
End of cable detected at 8434 ft. dBRL = 68.4+
FIGURE 8.11.4A - RESULTS OF THE SHDSL AUTO TEST - PASS
At the conclusion of the SHDSL AUTO test, the CableSHARK will report PASSED if all the user defined
thresholds are not compromised. Otherwise, the CableSHARK will report FAILED.
If the CableSHARK detects a load coil on the line as shown in Figure 8.11.4B, the SHDSL AUTO test will
halt and the CableSHARK will display NO DSL SERVICE POSSIBLE plus the distance to the load coil. Load
Coils must be removed from the circuit before xDSL services can be installed. The Single-End SHDSL test
will not be performed if this state arises.