VF / DSL Cable Qualifier
202
For temperatures in Celsius:
R
TC
= R
20°C
+ T
C
- 20°C ) * 0.00393 * R
20°C
]
Where R
TC
= new resistance based on new temperature in Celsius
T
C
= new temperature
R
20°C
= resistance of the cable @ 20°C
11. The RFL measurement is designed to find a single fault. If multiple faults exist, an incorrect
measurement will be given. If the result does not coincide with a splice point or equipment location,
then the test will have to re-done and the loop under test sectionalized to narrow down the location
of the impairment.