VF / DSL Cable Qualifier
164
MAIN
MENU
EF
CHG
VIEW
DETAIL
SAVE /
UPLOAD
DMM
Load Coil
Length(TDR)
Longitudinal Balance
Balance at 1kHz
Capacitance Imbalance
ADSL Upstream Rate =
ADSL Downstream Rate =
Disturber ID =
896 kbps Passed
7264 kbps Passed
undetermined
Passed
End of cable detected at 8434 ft. dBRL = 68.4+
FIGURE 8.11.2A - RESULTS OF THE ADSL AUTO TEST - PASS
At the conclusion of the ADSL, ADSL2 or ADSL2+ AUTO Test, the CableSHARK will report PASSED if all
the user defined thresholds are not compromised. Otherwise, the CableSHARK will report FAILED. Note that
some parameters may be skipped as well depending upon test environment.
If the CableSHARK detects a load coil on the line as shown in Figure 8.11.2B, the auto test will halt. Load
Coils must be removed from the circuit before xDSL services can be installed. The Single-End DMT test will
not be performed if this state arises.