Exfo CableSHARK P3 VF/DSL Cable Qualifier Manual de usuario Pagina 279

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 321
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 278
CableSHARK P3 User Guide
267
Longitudinal Balance Test
Single-end test: Near-End test plot with cursor & zoom
Frequency accuracy:
± 50 ppm
Accuracy: ± 2 dB
Vertical scale: 0 to 80.0 dB
Horizontal scale: 26 kHz to 2.2 MHz
DMM (Digital Multimeter)
For use on normal telephone network and broadband circuits
Mode: DMM-12 autotest, DMM-14 autotest or individual measurements
DC voltage:
Range: 0 to 400 V auto-ranging
Resolution: 3 significant digits
Accuracy: ±1% of reading ±1 LSD
AC voltage
Range: 0 to 250 Vrms auto-ranging
Resolution: 3 significant digits
Accuracy: ±1% of reading ±1 LSD
Resistance:
Range: 0 to 999 MΩ auto-ranging (30 MΩ for auto-test)
Resolution: 3 significant digits
Accuracy: 0 - 999 Ω, ±1% or ±5 Ω
1 kΩ - 99 MΩ, ±1% of reading ±1 LSD
100 MΩ to 999 MΩ, ±5% of reading ±1 LSD
Distance: Up to 100,000 ft (30,000 m)
Capacitance:
Range: 200 pF to 10 μF auto ranging, auto zeroing
Resolution: 3 significant digits
Accuracy: ±2% of reading ±1 LSD
Distance: Up to 100,000 ft (30,000 m)
Current:
DC Current: 0 to 110 mA
Vista de pagina 278
1 2 ... 274 275 276 277 278 279 280 281 282 283 284 ... 320 321

Comentarios a estos manuales