Test Results
Power Blazer 389
Summary (SyncE)
ESMC
Indicates the current (meter and value), average, minimum, and
maximum ESMC frame rate (including information and event frames)
received in frame/s. A fail verdict is also displayed beside the minimum
and/or maximum values when the ESMC frame rate is outside the range
while the Pass/Fail Verdict is enabled.
ESMC RX Rate meter displays the current ESMC frame rate (including
information and event frames) in frame/s averaged over the last 11 frames
received. The pass/fail verdict is also displayed when enabled.
Note: When the Pass/Fail Verdict and ESMC Rate Threshold check boxes are
selected (see page 237), the green region is delimited from 0.8 to 10.2
frames/s corresponding to a PA SS verdict. The red regions above and
beyond the threshold correspond to a FAIL verdict. There is neither green
nor red region when the Pass/Fail verdict is disabled.