Test Results
Power Blazer 347
S-OAM and MPLS-TP OAM
S-OAM and MPLS-TP OAM
From the Test menu, tap Results, and the S-OAM or MPLS-TP OAM tab.
Loopback
Status displays the status of the test function (refer to page 386).
TX LBM indicates the count of transmitted LBM frames.
RX LBR indicates the count of valid LBR frames received. A valid frame
for S-OAM has its source MAC address matching the Peer MEP MAC
address, destination MAC address matching the unit port MAC address,
and VLANs matching the unit port VLANs. A valid frame for MPLS-TP
OAM has its destination MAC address matching either the unit MAC
address, FF:FF:FF:FF:FF:FF, or 01:00:5E:90:00:00; VLANs matching the
unit port VLANs; and MPLS Labels matching the local MPLS Label
Stack configuration.
LBR Timeout
For connectivity verification (Continuous check box cleared), indicates
the count of LBR Timeout event which occurs if a reply (LBR frame
with matching Transaction ID) to a transmitted LBM frame is not
received within 5 seconds.
For diagnostic test (Continuous check box selected), indicates the
difference between the transmitted LBM frames and the received LBR
frames.
Invalid LBR
For connectivity verification (Continuous check box cleared), indicates
the count of LBR frames received from the peer MEP with incorrect
MEG/MD Level or with an unexpected Transaction ID.
For diagnostic test (Continuous check box is selected), indicates the
count of LBR frames received from the peer MEP with incorrect
MEG/MD Level.