Test Results
296 FTB/IQS-88000 Series
Alarms/Errors
S-OAM and MPLS-TP OAM
Alarms
Note: The following alarms are available when the CC Function check box is
selected (refer to page 183).
Loss Continuity
RX: No CCM frames with same or lower MEG/MD Level were received
from the peer MEP within an interval equal to 3.5 times the configured
CCM transmission period. The alarm is cleared when at least 3 CCM
frames with same or lower MEG/MD Level from the peer MEP are
received within an interval equal to 3.5 times the configured CCM
transmission period.
Mismerge
RX: A CCM frame was received from the peer MEP with same MEG/MD
Level but with incorrect MEG ID/MAID
1
value or format. The alarm is
cleared when no CCM frames with same MEG/MD Level but with
incorrect MEG ID/MAID
1
value or format are received within an interval
equal to 3.5 times the configured CCM transmission period.
Unexp MEG/MD Lvl (Unexpected MEG/MD Level)
RX: A CCM frames was received from the peer MEP with lower
MEG/MD Level. The alarm is cleared when no CCM frames with lower
MEG/MD Level are received within an interval equal to 3.5 times the
configured CCM transmission period.
1. The MAID, composed of a Domain ID and a Short MA Name strings, is incorrect if one or both strings are not as
expected.