Power Blazer 7
3 Getting Started
If the FTB/IQS-88000 Power Blazer Series has been purchased at the same
time as the platform, the FTB/IQS-88000 Series module is pre-installed with
the appropriate software version.
Equipment Rules for 88100NGE/88100G
There is a limitation on the number of FTB/IQS-88100NGE/88100G modules
and Transport and Datacom modules that can run simultaneously on a
FTB-500 and IQS-600 platforms due to 40G/100G CFP power consumption,
the following equipping rules are mandatory. For example with a 8-slot
FTB-500 platform, two 88xx modules can run simultaneously with either
three 8105, one 8510B, or one 8510G.
Platform Qty
a
a. Number of FTB/IQS-88100NGE/88100G that can run simultaneously.
Run simultaneously with either...
b
b. Each number represents the quantity of this module that can run simultaneously with the specified
number of FTB/IQS-88100NGE/88100G module without any other module. However these maximum
numbers are affected when mixing different modules.
88100NGE
88100G
8105
8805
8120NGE 8130NGE 8140 8525 8535 8510B 8510G 85100G 8830NGE
8830NGE-
16X
FTB-500
(4 slots)
110 0000000 0
FTB-500
(8 slots)
163 2132541 3
230 0000110 0
IQS-605P-HS 1 3 2 1 0 1 1 3 3 0 2
200 0000000 0
IQS-610P-HS 1 8 4 4 1 4 4 8 6 1 5
263 3133641 3
342 1021420 2
400 0000000 0
Comentarios a estos manuales