Test Setup - Test Configurator, Timer, and System
Power Blazer 187
S-OAM and MPLS-TP OAM
Frame Size allows to enter the frame size. The frame size range for
Ethernet II frame format is as follows:
S-OAM Mode: 64
12
to 1518
3
.
MPLS-TP OAM Mode: Minimum
1
and maximum values are as
follows:
The following table lists each parameter that may affect the minimum
and maximum
3
frame size value.
1. The minimum frame size is adjusted according to the frame structure and parameters selected.
2. For
Frame Loss
function, the frame size is not configurable and set to the minimum value.
3. For the Loopback function the maximum frame size is 16000 bytes for all rates at the exception of 10/100/1000Mbps
electrical interface which is 10000 bytes.
Test Function
MPLS-TP Mode
PW LSP Section
Loopback 68
a
to 16000
3
a. Add 4 bytes when the GAL check box is selected.
72 to 16000
3
68 to 16000
3
Test 68 to 1522 68 to 1522 64 to 1518
Frame Delay 68
ab
to 1522
b. Add 2 bytes when Test I D is selected as TLV Type.
72
b
to 1522 68
b
to 1518
Frame Loss
2
68 68 64
Parameter Number of bytes to be added Apply to
802.3 SNAP 8 bytes Y.1731, MEF,
G.8113.1
VLAN 4 bytes per VLAN (up to 3 VLAN)
Label 2 4 bytes G.8113.1
Continuous 18 bytes for Data TLV Type
21 bytes for Te st TLV Type
Requesting MEP ID TLV 56 bytes