Vista de pagina 91
RFC 2544
82 AXS-200/850
Throughput Results
Throughput Results
Press , select RFC 2544, Results, and the Throughput tab.
³ Status: Displays the test status as
“--”, In Progress, Completed, or
Aborted. Once the Throughput
test is completed or stopped, the
Pass/Fail verdict is displayed,
when enabled.
³ Max. Rate: Displays the
configured value of maximum
rate in Mbps or %.
Note: Max. Rate will not be displayed when the Dual Test Set parameter is set to
Local in Global Configuration on page 58.
³ Duration: Displays subtest duration in D HH:MM:SS format.
³ Val. #: Displays the configured number of validations.
³ Threshold: The throughput Pass/Fail threshold can be configured at all
times in Mbps or %. When the value is changed, the verdict of the
subtest gets re-evaluated and updated.
³ Results In: The throughput value is expressed in Mbps by default. The
user can also specify the values to be displayed as a percentage of the
line rate or in Frames per Second (fps).