Exfo AXS-200/850 Ethernet Test Set Manual de usuario Pagina 80

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 262
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 79
RFC 2544
70 AXS-200/850
Back-to-Back Configuration
³ Verdict Threshold: Set the threshold value in percentage of frames per
burst for the test. If the determined back-to-back value is greater or
equal to the threshold value, the test is declared as PASS. If the
determined back-to-back value for a specific frame size is lower than
the threshold value, the test is declared as FAIL. This value should
range from 0.1% to 100% and applies to all the 7 RFC 2544 frame sizes
or for the 7 user-defined frame sizes.
Note: When the Dual Test Set parameter is
set to Local in Global Configuration
on page 58, the Verdict Threshold is
configured independently for each
direction: Local-to-Remote and
Remote-to-Local.