BERT
Ethernet Test Set 105
Summary Results
Summary Results
The Summary Results page allows the user to not only view the status of
the test, but to also change certain parameters dynamically as the test is
running, such as injecting and resetting errors, changing the transmission
rate, frame size, and threshold.
Press , select BERT, Results, and the Summary tab.
³ Status: The BERT test progress is
monitored and updated on a per
second basis. The status displays
the following:
³ --”: test is not running and
results are not available.
³ In Progress: test is running.
³ Completed: test is completed,
stopped at the planned time, or manually stopped when there is no
set timer.
³ Aborted: test is interrupted; test is stopped before the set time.
Once the BERT test is stopped, the Pass/Fail verdict is displayed, when
enabled.
IMPORTANT
Test results/statistics are cleared when changing test or tool
selection. It is highly advised to generate and save the report once
the current test is completed. Refer to Report Generation on
page 79 to generate and save a report file.