Exfo AXS-200/850 Ethernet Test Set Manual de usuario Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 262
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
BERT
Ethernet Test Set 97
Global Configuration
Global Configuration
The rate and frame size can be changed dynamically while the test is
running. The Pass/Fail verdict can be set at anytime independent of
whether a test is started.
Press , select BERT, Configuration, and the Global tab.
Note: Service Disruption Time feature is always active.
³ Framing: Select Ethernet,
Ethernet/IPv4/UDP or
Ethernet/IPv6/UDP. The default
value is Ethernet.
³ Rate Unit: Select the unit for the
transmission and receive rate.
Choices are Mbps and %. The
default setting is Mbps.
³ TX Rate: Set the transmission rate
in terms of a percentage of the line rate or in Mbps.
The accepted range and increments are as follows:
Interface Maximum Rate
% Mbps
10 Mbps 0.1 - 100,
default = 100
0.01 - 10, default = 10
100 Mbps 0.1 - 100, default = 100
1000 Mbps 1 - 1000, default = 1000