Exfo FTB-800 Series for FTB-1 Manual de usuario Pagina 286

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 621
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 285
Test Results
276 FTB-700G/800 Series
Alarms/Errors
S-OAM
Alarms
Note: The following alarms are available when the CC Function check box is
selected (refer to page 184).
Loss Continuity
RX: No CCM frames were received from the peer MEP within an
interval equal to 3.5 times the configured CCM transmission period.
The alarm is cleared when at least 3 CCM frames from the peer MEP
are received within an interval equal to 3.5 times the configured CCM
transmission period.
Mismerge
RX: A CCM frame was received from the peer MEP with correct
MEG/MD Level but with incorrect MEG ID/MAID. The alarm is cleared
when no CCM frames with incorrect MEG ID/MAID are received within
an interval equal to 3.5 times the configured CCM transmission period.
Unexp MEP (Unexpected MEP)
RX: A CCM frame was received from the peer MEP with correct
MEG/MD Level, MEG ID/MAID, and source MAC Address (corresponds
to the peer MEP) but with unexpected MEP ID. The alarm is cleared
when no CCM frames with an unexpected MEP ID are received within
an interval equal to 3.5 times the configured CCM transmission period.
Unexp MEG/MD Lvl (Unexpected MEG/MD Level)
RX: A CCM frames was received from the peer MEP with incorrect
MEG/MD Level (MEG/MD Level received is lower than local MEG/MD
Level). The alarm is cleared when no CCM frames with incorrect
MEG/MD Level are received within an interval equal to 3.5 times the
configured CCM transmission period.
Vista de pagina 285
1 2 ... 281 282 283 284 285 286 287 288 289 290 291 ... 620 621

Comentarios a estos manuales

Sin comentarios