Test Setup - Test Configurator, Timer, and System
NetBlazer 95
Signal Auto-Detect
For Wireless Test Application
Interface/Rate allows the selection of the interface rate: 2.4576G or
3.072G (default).
Connector allows the selection of the module’s port: Port 1 - SFP or
Port 2 - SFP.
Signal Auto-Detect
The Signal Auto-Detect allows the detection of the DS1/DS3 interface
Line Coding (DS1), Framing, and Test Pattern.
Signal Auto-Detect is only available:
with DS1 and DS3 interfaces.
when the test is stopped.
when Loopback is not activated for NI/CSU Emulation test.
Note: Test Pattern is not detected with NI/CSU Emulation and ISDN PRI test
applications.
During the detection process, the following messages may be displayed:
Detecting, Successful, and/or Failed.
When the auto-detection is successful, the detected parameters are
automatically applied as the test interface configuration.
Upon detection of specific alarms, the detection may not be possible, tap
Retry to invoke the detection again.