Test Setup - Test Configurator, Timer, and System
NetBlazer 201
Signal (Transport)
TX Frequency
Note: Frequency offset is not available when Through mode is selected.
TX Frequency (GHz) indicates the frequency (actual frequency +
Frequency offset) used for transmission.
Offset (ppm) check box, when selected (cleared by default), allows to
set the frequency offset that will be generated. Use the “+” or “-”
button to respectively increment or decrement the frequency offset
value based on the defined Increment/Decrement Size, or directly
type the frequency offset value in the field. Possible offsets for
Transport test applications are listed in the following table.
Interface Frequency Offset
a
Nominal Frequency
DS1 ±140 ppm 1544000 bit/s
E1 ± 70 ppm 2048000 bit/s
E3 ± 50 ppm 34368000 bit/s
DS3 44736000 bit/s
STS-1e/STM-0e 51840000 bit/s
E4 139264000 bit/s
STS-3e/STM-1e 155520000 bit/s
OC-1/STM-0 ± 50 ppm 51840000 bit/s
OC-3/STM-1 155520000 bit/s
OC-12/STM-4 622080000 bit/s
OC-48/STM-16 2488320000 bit/s
OC-192/STM-64 9953280000 bit/s
OTU1 ± 50 ppm 2666057143 bit/s
OTU2 ± 50 ppm (Framed)
± 120 ppm (Unframed)
10709225316 bit/s