Test Setup - Test Configurator, Timer, and System
NetBlazer 193
Services - Profile
Note: The CIR value will be calculated on the basis of the selected service profile
and the value entered in the Number of Calls or Number of Channels
field.
Frame Size (Bytes) indicates the frame size for Voice and Video
profiles and allows to change the frame size for Data profile:
Fixed (default)
Profile and
Codec
Type
Frame Size (bytes)
IPv4 IPv6
Voice Codec:
- VoIP G.711
- VoIP G.723.1
- VoIP G.729
Fixed
138
82
78
158
102
98
Video Codec:
All
Fixed 1374 1394
Data Fixed (default) 64
a
(default) to 10000
a. The minimum value is adjusted according to the frame structure and components
selected as shown in the following table.
Random 64
a
to 1518
b
b. The maximum frame size vale is adjusted for each enabled VLAN (+4 bytes per
VLAN).
EMIX 64
a
to 10000