Multimeter Tests
Copper Test 159
Resistive Balance Test
Setting Threshold Values
The Test Thresholds page allows you to set the Resistive Balance
Threshold values for the test, in
and %.
To set the Threshold values:
1. From the Copper main menu Test Groups, select Multimeter test
.
2. From the Tests menu, select Resistive Balance test.
3. Tap Snapshot tab to set the Threshold values.
4. Tap Edit Thresholds button to open the Test Thresholds page.
5. Set the Threshold values as required.
6. Tap Close to confirm and exit the page.
The page allows you to set the following parameters:
Threshold is the threshold limit for each pair: Maximum, Minimum, or
None.
Threshold Resistive Balance sets the threshold value.