Vista de pagina 113
Auto Test
106 FTB-610
User Auto Test
User Auto Test Selection
The Test Selection page allows you to select up to 13 test types to include
in the auto test, and set a Pause between tests by selecting Pause check
box. All listed tests have a fixed duration (snapshot) and are not
continuous. Graphs are not displayed.
To select the test:
1. From the Copper main menu Test Groups, select Auto Test
.
2. From the Tests menu, select User Auto Test to start the test.
3. Tap Test Selection button to open a new page.
4. Select the tests to run.
5. Tap Close to confirm and exit the page.
The following tests are available:
Voltage detects AC RMS and DC voltages in the line.
Current checks for AC RMS and DC currents in the line.
Resistance uses DC current to measure the opposition to flow, or
resistance, between each of the lead combinations. It is also used to
identify possible faults, and to measure the resistance of the twisted
pair cable for estimating loop length.