RFC 2544 Tabs
262 FTB-8500 Series and FTB-8120NGE/8130NGE
Frame Loss Configuration
Nb of trials to average: Select the number of times the test will be
generated. Choices are 1 to 50 trials. The default setting is 1 trial.
Maximum Rate
TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local: Select
the maximum rate for the test. The default setting is 100 % for
10/100/1000Mbps and 10Gig-E LAN, and 92.8571428571429% for
10Gig-E WAN. P1-to-P2/P2-to-P1 is only available with FTB-8510B.
Select the rate’s unit. Choices are %, and Mbps/Gbps. The default
setting is %.
Minimum Test Time (Seconds): Indicates the minimum time the test
requires to run at best condition. The minimum test time is calculated
and updated once the test is started.
Unit Interface
Rate
from to
% 10Base-T
100Base-T
1000Base-T/X
10Gig-E LAN
10Gig-E WAN
1
1
1
1
1
100
100
100
100
92.8571428571429
Mbps 10Base-T
100Base-T
1000Base-T/X
0.1
1
10
10
100
1000
Gbps 10Gig-E LAN
10Gig-E WAN
0.1
0.1
10.0
9.2857142857142865