Exfo FTB-8500 Series for FTB-200 Manual de usuario Pagina 212

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 513
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 211
Traffic Analyzer Tabs
198 FTB-8500 Series and FTB-8120NGE/8130NGE
FC RX
FC RX
Press Main, Test, Traffic Analyzer, and FC RX.
Alarm Analysis
Link Down: Indicates that the fibre channel connection is down. The
fibre channel connection is down if there is a local or a remote fault
condition including LOS, loss of code-group synchronization, and PSP
failure (when enabled).
Local Fault (FC 10x): Indicates that at least one of the following events
is detected: LOS, Loss of bit synchronization, Loss of Block
synchronization, Link down, or High BER (High BER is true when the
bit error ratio > 10
-4
on a fixed 125 μs time period).
Remote Fault (FC 10x): Indicates that a Remote Fault event is
detected.
Note: Alarms/Errors are updated only during test execution.
Vista de pagina 211
1 2 ... 207 208 209 210 211 212 213 214 215 216 217 ... 512 513

Comentarios a estos manuales

Sin comentarios