Exfo FTB-8500 Series for FTB-200 Manual de usuario Pagina 181

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 513
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 180
Traffic Analyzer Tabs
Ethernet and Fibre Channel Application 167
Ethernet RX
Ethernet RX
Press Main, Test, Traffic Analyzer, and Eth. RX.
Configuration
Oversize Monitoring
Enables the monitoring of the Oversize error.
Alarms Analysis
Link Down: Indicates that the Ethernet connection is down. The
Ethernet connection is down when there is a local or a remote fault
condition.
Local Fault (10Gig-E): Indicates that at least one of the following
events is detected: LOS, Loss of bit synchronization, Loss of Block
synchronization, WIS Link down, or High BER (High BER is true
when the bit error ratio > 10
-4
on a fixed 125 μs time period).
Remote Fault (10Gig-E): Indicates that a Remote Fault event is
detected.
Note: Alarms/Errors are updated only during test execution.
Vista de pagina 180
1 2 ... 176 177 178 179 180 181 182 183 184 185 186 ... 512 513

Comentarios a estos manuales

Sin comentarios