Traffic Analyzer Tabs
164 FTB-8500 Series and FTB-8120NGE/8130NGE
Ethernet TX
Ethernet TX
Note: Available with BERT test with Framed Layer 1 and Framed Layer 2 only.
Press Main, Test, Traffic Analyzer, and Eth. TX.
PHY Alarm Generation
Note: Available with 10Gig-E interface only.
Type: The following alarms are available:
Link Down: Generates a continuous PCS error (block error).
Local Fault: Generates a local fault sequence.
Remote Fault: Generates a remote fault sequence.
On/Off button: The On/Off button is used to activate/deactivate the
selected alarm. This setting is disabled (Off) by default.