NOTES
a. All specifications are for a temperature of 23 °C (73 °F) with an SC/PC connector unless
otherwise specified.
b. MTP connectors are sensitive to dirt. Protection and cleanup before and after each use is recommended.
c. Typical insertion loss per module, excluding connectors, measured at singlemode wavelengths
of 1310 nm and 1550 nm.
d. Typical backreflection measured at singlemode wavelengths of 1310 nm and 1550 nm,
excluding connectors.
e. Typical repeatability values for 100 cycles per switch module at a constant temperature for
1 hour with a stabilized source/power meter at singlemode wavelengths of 1310 nm and 1550 nm.
f. Typical.
g. Configuration 54–SC/PC is offered for singlemode or multimode fiber types.
h. Configuration 88-SC/APC is offered for singlemode fiber types only.
i. Configuration E-2000 is offered for singlemode fiber types only.
SPECIFICATIONS
a
FTB-85102 FTB-8510-12 FTB-8510-2
Ports Gigabit Ethernet Two 10/100Base-T Two 10/100Base-T Two 10/100Base-T and two
and one Gigabit Ethernet
Connector types RJ-45 (ISO 8877) RJ-45 (ISO 8877) and LC RJ-45 (ISO 8877) and LC
Connect speed (Mb/s) 10/100 10/100/1000 10/100/1000
Duplex mode Full/half-duplex Full/half-duplex Full/half-duplex
auto-negotiation auto-negotiation auto-negotiation
Maximum port capacity (Mb/s) 200 (bidirectional) 2000 (bidirectional) 2000 (bidirectional)
Ethernet testing RFC 2544 RFC 2544 RFC 2544
RFC 1242 RFC 1242 RFC 1242
SPECIFICATIONS
a
Model FTB-9100-01-12-B-XX FTB-9100-01-12-B-92-XX FTB-9100-01-12-B-92-XX
Singlemode Singlemode Multimode
Number of channels 1x12 1x12 1x12
Connector type SC/PC (54), E-2000/PC (95) MTP/APC SC/PC (54)
SC/APC (88), E-2000/APC (96) (female connector)
b
Insertion loss
c
(dB) 0.7 0.9 0.5
Backreflection
d
(dB) —40 (PC) —55 —24
—55 (APC)
Repeatability
e
(dB) ± 0.03 ± 0.03 ± 0.03
Operating wavelengths (nm) 1290 to 1650 1290 to 1650 78 0 to 1350
Polarization dependent loss (dB) 0.05
f
0.05
f
—
Crosstalk (dB) —80 —80 —80
Switch life 10 million cycles minimum (excluding connector cycles)
Maximum optical input power 24 dBm 24 dBm 24 dBm
GENERAL SPECIFICATIONS
a
Temperature
operating 10 °C to 40 °C (50 °F to 104 °F)
storage —20 °C to 60 °C (–4 °F to 140 °F)
Relative humidity 80 % max. non-condensing
Size (H xWxD) 96mmx51mmx260mm (3
3
/
4
in x 2 in x 10
1
/
4
in)
Weight 1.0 kg (2.2 lb)
Comentarios a estos manuales