Testing Fibers in Advanced Mode
48 FTB-700 Series
Enabling or Disabling Analysis After Acquisition
Enabling or Disabling Analysis After
Acquisition
The OTDR trace acquisition procedure will be completed by the analysis.
You can either choose to automatically analyze each trace immediately
after the acquisition, or perform the analysis whenever it suits you best.
When the analysis process is disabled, the Event table of a newly acquired
trace will be empty.
You can also set a default fiber span, which will be applied during the
analysis of all traces to display test results. For details, see Setting a Default
Span Start and Span End on page 55.
Note: In Auto mode, the application always performs an analysis after the
acquisition.