Connection Setup for IP Triple-Play Verification Tests
10 AXS-200/650
Setup Line Connection
Setup Line Connection
Line Parameters
The Line Params tab allows you to set the Ethernet negotiation modes for
a Selected Profile composed of the current AccessMode selections.
When the LineMode selection is
Ethernet, the available parameters are
the following:
³ Link Speed is a choice between
AUTO (negotiated during the link
establishment), 100 or 10 Mbps.
³ Connect Mode is Full-duplex or
Half-duplex, when Link Speed is
set to either 100 or 10 Mbps.
To select the line parameters to configure:
1. From the Connection Setup pane, press the left/right function arrows
until the Line Params tab is displayed.
2. Press the F1, F2, or F3 key located just below the tab to select it.
3. Press the up/down arrows to select the desired parameter.
4. Press to open the list or modify the parameter.
5. In the list, press the up/down arrows to select the function or mode.
OR
Use the alphanumeric keypad to enter the value you want to specify.
6. Press to confirm the selection.