Exfo MaxTester 635 Manual de usuario Pagina 101

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 355
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 100
Copper and VDSL2/ADSL2+ Multi-play Test Set 93
7 Multimeter Tests
The purpose of the multimeter tests function is to detect AC/DC voltages
and currents, and measure resistance and capacitance in a loop. These
tests allow you to make basic electrical safety checks (AC volts), check for
crossed or coupled battery voltages, assess basic loop continuity and
quality with resistance measurements, and measure total electrical length
with capacitance.
To access Multimeter tests:
From the Copper Main pane, highlight Multimeter and press to open
the Multimeter menu.
Multimeter Main Page
The Multimeter menu allows you to select and run
the displayed tests:
Voltage
Current
Resistance
Resistive Balance
Isolation
Capacitance/Opens
Station Ground
Stressed Balance
To start/stop a test:
1. Press the up/down left/right arrow keys on the keypad to select the
desired test icon.
2. Press to confirm your selection.
3. The test will start automatically if the Setup/Application Settings - Test
Startup Mode is set to Auto. If not, press Start/Stop on the keypad.