Exfo MAX-710-P Manual de usuario Pagina 115

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 381
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 114
Customizing the OTDR Application
MAX-700 103
Customizing the Acquisition Time Values
Customizing the Acquisition Time Values
Note: This function is available in Advanced mode only.
You can customize the values associated with the Time dial. The
acquisition time values represent the time during which the OTDR will
average acquisitions.
Note: The Auto and Real values cannot be modified.
You can customize the acquisition time to improve the signal-to-noise ratio
(SNR) of the trace and enhance the detection of low-level events. The SNR
improves by a factor of two (or 3 dB) each time the acquisition time is
increased by a factor of four.
Vista de pagina 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 380 381

Comentarios a estos manuales

Sin comentarios