Exfo iOLM Manual de usuario

Busca en linea o descarga Manual de usuario para Instrumentos de medición Exfo iOLM. EXFO iOLM User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 186
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - User Guide

User Guideintelligent Optical Link MapperiOLM

Pagina 2

Introducing the intelligent Optical Link Mapper4 iOLMOTDR port (singlemode live)OTDR port (singlemode)Active LED(on when laser is emitting)MAX-700B Se

Pagina 4

intelligent Optical Link Mapper 959 Using the Inline Power Meter (Optional on Some Models)This section will help you use the inline power meter and pe

Pagina 5

Using the Inline Power Meter (Optional on Some Models)96 iOLMUnderstanding the Inline Power MeterA visual representation of the power value for each c

Pagina 6 - Certification Information

Using the Inline Power Meter (Optional on Some Models)intelligent Optical Link Mapper 97Performing a Power Meter AcquisitionPerforming a Power Meter A

Pagina 7 - Optical Link Mapper

Using the Inline Power Meter (Optional on Some Models)98 iOLMSaving the Power LevelWhen both wavelengths of a two-channels power meter are selected, b

Pagina 8

Using the Inline Power Meter (Optional on Some Models)intelligent Optical Link Mapper 99Saving the Power LevelThe saved power level is also displayed

Pagina 9 - Singlemode and

Using the Inline Power Meter (Optional on Some Models)100 iOLMiOLM Acquisition with Power MeteriOLM Acquisition with Power MeterThe iOLM and power met

Pagina 10 - MAX-700B Series

Using the Inline Power Meter (Optional on Some Models)intelligent Optical Link Mapper 101iOLM Acquisition with Power Meter3. Select the SM Live Port a

Pagina 12

intelligent Optical Link Mapper 10310 Using the OTDR as a Source (Optional on Some Models)The Source tab allows you to operate the existing OTDR laser

Pagina 13

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 5Principles of OperationPrinciples of OperationThe iOLM application use

Pagina 14

Using the OTDR as a Source (Optional on Some Models)104 iOLM2. Select the desired wavelength from the Wavelength list.

Pagina 15

Using the OTDR as a Source (Optional on Some Models)intelligent Optical Link Mapper 1053. Select the desired modulation from the Modulation list. Sele

Pagina 17

intelligent Optical Link Mapper 10711 Starting the OTDR ApplicationYou can start the classic OTDR application without leaving the iOLM application. Yo

Pagina 18

Starting the OTDR Application108 iOLM2. Tap Start to start the OTDR acquisition. For more information, refer to the OTDR user guide.Note: The aspect o

Pagina 19 - 2 Safety Information

intelligent Optical Link Mapper 10912 Managing ResultsThis section explains the link view, measurement information, element details, and the results d

Pagina 20

Managing Results110 iOLMLink ViewLink OverviewThe link overview shows the entire link without scrolling. You can directly select an element by tapping

Pagina 21 - Safety Information

Managing Resultsintelligent Optical Link Mapper 111Link ViewElements before A and after B are referred to as out of span elements. Elements out of the

Pagina 22

Managing Results112 iOLMLink View Letter B: The end of the link under test.Note: An arrow ( ) icon is displayed on the element, if the start and the

Pagina 23 - 3 Getting Started with Your

Managing Resultsintelligent Optical Link Mapper 113Link View Loop Start icon : Indicates the beginning of the loop. Loop End icon : Indicates the

Pagina 24 - Status Bar

Introducing the intelligent Optical Link Mapper6 iOLMPerforming Multimode MeasurementsPerforming Multimode MeasurementsIf your module supports multimo

Pagina 25

Managing Results114 iOLMLink ViewLink GroupsLink elements will be displayed as groups when the iOLM analysis detects several link elements that are to

Pagina 26

Managing Resultsintelligent Optical Link Mapper 115Link ViewEach sub-element is directly displayed as if they were normal elements. See Link Compositi

Pagina 27

Managing Results116 iOLMLink ViewLink View ElementsElement Name Element Icon Element DescriptionMacrobends Macrobends can be displayed in the link vie

Pagina 28

Managing Resultsintelligent Optical Link Mapper 117Link ViewiOLM ResultsThe iOLM acquisition results are displayed in the iOLM table for all the wavel

Pagina 29 - 5 Setting User Preferences

Managing Results118 iOLMLink ViewPower Meter ResultsThe power meter acquisition results are displayed in the OPM table for all the wavelengths at whic

Pagina 30 - Defining General Settings

Managing Resultsintelligent Optical Link Mapper 119Link ViewLoopback ResultsThe loopback measurement is especially designed for testing cables formed

Pagina 31

Managing Results120 iOLMLink ViewGlobal Pass/Fail StatusThe global pass/fail status depends on the pass/fail status of the link length, link loss, lin

Pagina 32

Managing Resultsintelligent Optical Link Mapper 121Viewing Element and Section DetailsViewing Element and Section DetailsWhen an element or section is

Pagina 33 - Numeric and alphanumeric

Managing Results122 iOLMViewing Element and Section Details2. From the main window, tap the Elements tab. You can view the selected element or section

Pagina 34 - Customizing the File Name

Managing Resultsintelligent Optical Link Mapper 123Viewing Element and Section Details In loopback mode, the application displays the link start (A),

Pagina 35 - 2. Select the Filename tab

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 7Launch, Receive, and Loop FiberLaunch, Receive, and Loop FiberUnlike a

Pagina 36

Managing Results124 iOLMViewing Element and Section DetailsNote: If the type of an element is modified, a “*” sign is displayed at the value in the Ty

Pagina 37

Managing Resultsintelligent Optical Link Mapper 125Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)Managing Elements a

Pagina 38

Managing Results126 iOLMManaging Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)To add an element:1. Open an iOLM file.2. Sele

Pagina 39 - Next file name

Managing Resultsintelligent Optical Link Mapper 127Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)4. In the New Eleme

Pagina 40

Managing Results128 iOLMManaging Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)The application also allows you to add an elem

Pagina 41

Managing Resultsintelligent Optical Link Mapper 129Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)4. Enter the positi

Pagina 42

Managing Results130 iOLMManaging Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)When you add a new element to an element or gr

Pagina 43 - Customizing the iOLM Report

Managing Resultsintelligent Optical Link Mapper 131Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)Deleting ElementsTh

Pagina 44

Managing Results132 iOLMManaging Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)4. Select Delete Element from the contextual m

Pagina 45

Managing Resultsintelligent Optical Link Mapper 133Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)To analyze the link

Pagina 46

Introducing the intelligent Optical Link Mapper8 iOLMLaunch, Receive, and Loop Fiberreceive fiber has the same limitations than that of a traditional

Pagina 47

Managing Results134 iOLMMeasurement InformationMeasurement InformationYou can find information about a measurement, in the application, such as the fi

Pagina 48 - Configuring your iOLM

Managing Resultsintelligent Optical Link Mapper 135Measurement InformationTo view identification information:1. From the main window tap Measurement I

Pagina 49

Managing Results136 iOLMMeasurement InformationTo view measurement settings:1. From the main window, tap Measurement Info.2. Tap Settings.3. By defaul

Pagina 50

intelligent Optical Link Mapper 13713 Managing FilesThe File menu allows you to open an existing file, save a file, and generate a report from the mea

Pagina 51

Managing Files138 iOLMOpening iOLM Files2. Tap Open.3. Select the file you want to open and tap Open.Note: Depending on the type of unit you are using

Pagina 52 - 2. Tap Select

Managing Filesintelligent Optical Link Mapper 139Saving iOLM FilesSaving iOLM FilesThe Save or Save As menu item allows you to save an existing iOLM f

Pagina 53

Managing Files140 iOLMSaving iOLM Files2. Tap either Save to overwrite the existing file with the new file, or Save As to enter a new name or location

Pagina 54

Managing Filesintelligent Optical Link Mapper 141Saving iOLM Files3. Enter the file name and tap Save.Note: Depending on the type of unit you are usin

Pagina 55 - Creating a Test Configuration

Managing Files142 iOLMExporting OTDR Bellcore FilesExporting OTDR Bellcore FilesThe Export option allows you to manually export a OTDR Bellcore file t

Pagina 56 - 4. Tap Duplicate

Managing Filesintelligent Optical Link Mapper 143Exporting OTDR Bellcore Files2. Tap Export to save the file in .sor format.

Pagina 57

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 9Launch, Receive, and Loop FiberThe loopback measurement is designed to

Pagina 58 - Modifying Identifiers

Managing Files144 iOLMExporting OTDR Bellcore Files3. The default file name is displayed in the File name field. You can edit the file name and tap Sa

Pagina 59

Managing Filesintelligent Optical Link Mapper 145Generating a ReportGenerating a ReportThe Report menu item allows you to generate an iOLM report, Pow

Pagina 60 - Modifying Link Definition

Managing Files146 iOLMGenerating a ReportTo generate a report:1. From the Main Menu, tap File.2. Tap Report.

Pagina 61 - To modify link definition:

Managing Filesintelligent Optical Link Mapper 147Generating a Report3. Enter the report file name and tap Save.Note: Depending on the type of unit you

Pagina 63

intelligent Optical Link Mapper 14914 MaintenanceTo help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them

Pagina 64

Maintenance150 iOLMCleaning EUI ConnectorsTo clean EUI connectors:1. Remove the EUI from the instrument to expose the connector baseplate and ferrule.

Pagina 65 - Mode Only)

Maintenanceintelligent Optical Link Mapper 151Cleaning EUI Connectors6. Clean the ferrule in the connector port as follows:6a. Deposit one drop of iso

Pagina 66

Maintenance152 iOLMRecalibrating the UnitRecalibrating the UnitEXFO manufacturing and service center calibrations are based on the ISO/IEC 17025 stand

Pagina 67 - 5. Enable 2:N splitter

Maintenanceintelligent Optical Link Mapper 153Recycling and Disposal (Applies to European Union Only)To help you with calibration follow-up, EXFO prov

Pagina 68

Introducing the intelligent Optical Link Mapper10 iOLMSoftware OptionsSoftware OptionsSoftware options are offered with your unit. The iOLM software

Pagina 70

intelligent Optical Link Mapper 15515 TroubleshootingViewing Online DocumentationAn online version of the intelligent Optical Link Mapper user guide i

Pagina 71

Troubleshooting156 iOLMContacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technical support

Pagina 72

Troubleshootingintelligent Optical Link Mapper 157Viewing Information About the ProductViewing Information About the ProductYou can view the product v

Pagina 73

Troubleshooting158 iOLMTransportationTransportationMaintain a temperature range within specifications when transporting the unit. Transportation damag

Pagina 74

intelligent Optical Link Mapper 15916 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship

Pagina 75

Warranty160 iOLMLiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any failure

Pagina 76 - 4. Tap Modify

Warrantyintelligent Optical Link Mapper 161ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its pro

Pagina 77

Warranty162 iOLMService and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the date of purcha

Pagina 78

Warrantyintelligent Optical Link Mapper 163EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact you

Pagina 79

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 11ConventionsConventionsBefore using the product described in this guid

Pagina 81

intelligent Optical Link Mapper 165A Technical SpecificationsFTB-720IMPORTANTThe following technical specifications can change without notice. The inf

Pagina 82

Technical Specifications166 iOLMFTB-720GFTB-720GNote: The following specifications are for the OTDR instrument. Refer to the Transport Application use

Pagina 83

Technical Specificationsintelligent Optical Link Mapper 167FTB-730FTB-730TECHNICAL SPECIFICATIONS (OTDR)Model FTB-730 aWavelength (nm) b1310 ± 20/1490

Pagina 84

Technical Specifications168 iOLMFTB-730GFTB-730GNote: The following specifications are for the OTDR instrument. Refer to the Transport Application use

Pagina 85 - Deleting Test Configuration

Technical Specificationsintelligent Optical Link Mapper 169FTB-7300EFTB-7300ETECHNICAL SPECIFICATIONSModelFTB-7300E aWavelength (nm) b1310 ± 20/1490 ±

Pagina 86

Technical Specifications170 iOLMFTB-7400EFTB-7400EAll specifications valid at 23 °C ± 2 °C with an FC/APC connector, unless otherwise specified. TECHN

Pagina 87

Technical Specificationsintelligent Optical Link Mapper 171MAX-715BMAX-715BTECHNICAL SPECIFICATIONS MAXTESTER 715BDisplay 7 in (178 mm) outdoor-enhanc

Pagina 88 - 3. Tap Import

Technical Specifications172 iOLMMAX-720BMAX-720BTECHNICAL SPECIFICATIONS MAXTESTER 720BDisplay 7 in (178 mm) outdoor-enhanced touchscreen, 800 x 480 T

Pagina 89

Technical Specificationsintelligent Optical Link Mapper 173MAX-730BMAX-730BTECHNICAL SPECIFICATIONS MAXTESTER 730BDisplay 7 in (178 mm) outdoor-enhanc

Pagina 92

Indexintelligent Optical Link Mapper 175IndexAadd element ... 125after-sales service ...

Pagina 93 - 7 Starting an Acquisition

Index176 iOLMimporting a test configuration ... 81iOLM wavelength(s) ... 43IOR ...

Pagina 94

Indexintelligent Optical Link Mapper 177splice... 116splitter ratio ...

Pagina 95 - 3. Tap Start

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Pagina 96

MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( ㄃ )Logo㪖㉦This E;)2 product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl

Pagina 97

www.EXFO.com · [email protected]/N: 1067569CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Pagina 98 - Stopping an Acquisition

intelligent Optical Link Mapper 132 Safety InformationWARNINGDo not install or terminate fibers while a light source is active. Never look directly in

Pagina 99 - 8 Understanding Diagnostics

ii iOLMCopyright © 2011–2015 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted

Pagina 100

Safety Information14 iOLMLaser Safety Information (Units Without a VFL)Laser Safety Information (Units Without a VFL)Your instrument is a Class 1M las

Pagina 101 - (Optional on Some Models)

Safety Informationintelligent Optical Link Mapper 15Laser Safety Information (Units Without a VFL)Laser information of the VFL. Always refer to the us

Pagina 102

Safety Information16 iOLMLaser Safety Information (Units With a VFL)Laser Safety Information (Units With a VFL)Your instrument is a Class 3R laser pro

Pagina 103

intelligent Optical Link Mapper 173 Getting Started with Your iOLMNote: Please refer to your platform's or unit’s user guide for detailed informa

Pagina 104 - Saving the Power Level

Getting Started with Your iOLM18 iOLMStatus BarStatus BarThe status bar, located at the bottom of the main window, identifies the selected configurati

Pagina 105 - View tab

intelligent Optical Link Mapper 194 Preparing your iOLM for a TestCleaning and Connecting Optical FibersTo connect the fiber-optic cable to the port:1

Pagina 106 - 100 iOLM

Preparing your iOLM for a Test20 iOLMCleaning and Connecting Optical Fibers3. Carefully align the connector and port to prevent the fiber end from tou

Pagina 107

Preparing your iOLM for a Testintelligent Optical Link Mapper 21Installing the EXFO Universal Interface (EUI)Installing the EXFO Universal Interface (

Pagina 109

intelligent Optical Link Mapper 235 Setting User PreferencesThe User Preferences window allows you to set general settings, identification settings, a

Pagina 110 - 104 iOLM

Contentsintelligent Optical Link Mapper iiiContentsCertification Information ...

Pagina 111

Setting User Preferences24 iOLMDefining General Settings2. Select the General tab.3. Under the General tab, configure the following settings: File Fu

Pagina 112

Setting User Preferencesintelligent Optical Link Mapper 25Defining General Settings Export OTDR Bellcore (.sor) file on save: If enabled, an OTDR Bel

Pagina 113

Setting User Preferences26 iOLMDefining Measurement IdentificationDefining Measurement IdentificationYou can define the measurement identification inf

Pagina 114 - Starting the OTDR Application

Setting User Preferencesintelligent Optical Link Mapper 27Defining Measurement Identification2. Select the Identification tab.3. Define the identifica

Pagina 115 - 12 Managing Results

Setting User Preferences28 iOLMCustomizing the File NameCustomizing the File NameThe application provides a way to define the name of the file to be s

Pagina 116 - Link Overview

Setting User Preferencesintelligent Optical Link Mapper 29Customizing the File Name2. Select the Filename tab.Standard measurementLoopback measurement

Pagina 117 - Link Composition

Setting User Preferences30 iOLMCustomizing the File Name3. Select which component you want to include in the file name from the list of available choi

Pagina 118

Setting User Preferencesintelligent Optical Link Mapper 31Customizing the File Name5. If you have the loopback (LB) software option, under Loopback pr

Pagina 119 - Link View

Setting User Preferences32 iOLMCustomizing the File Name6. Tap Apply to save the changes. 7. Tap OK to save the changes and close the window, or tap C

Pagina 120 - Link Groups

Setting User Preferencesintelligent Optical Link Mapper 33Naming iOLM Files AutomaticallyNaming iOLM Files AutomaticallyEach time you start an acquisi

Pagina 121

Contentsiv iOLM7 Starting an Acquisition ...87Starting an iOLM Acquisition

Pagina 122 - Link View Elements

Setting User Preferences34 iOLMNaming iOLM Files AutomaticallyConsider the figure below as an example of autonaming feature.You can find the above win

Pagina 123

Setting User Preferencesintelligent Optical Link Mapper 35Naming iOLM Files AutomaticallySelect two, three, or four "#" if you want all valu

Pagina 124 - Power Meter Results

Setting User Preferences36 iOLMNaming iOLM Files AutomaticallyAfter an acquisition is successfully saved, the file name is the combination of job ID,

Pagina 125 - Loopback Results

Setting User Preferencesintelligent Optical Link Mapper 37Customizing the iOLM ReportCustomizing the iOLM Report The application allows you to persona

Pagina 126 - Global Pass/Fail Status

Setting User Preferences38 iOLMCustomizing the iOLM Report3. If your unit allows it, select the report file type from File type option.4. Select the O

Pagina 127 - Loopback mode

Setting User Preferencesintelligent Optical Link Mapper 39Customizing the iOLM Report7. If you have the loopback (LB) software option, under Loopback,

Pagina 128 - 122 iOLM

Setting User Preferences40 iOLMCustomizing the Optical Power MeterCustomizing the Optical Power MeterThe OPM tab is available when an inline power met

Pagina 129

Setting User Preferencesintelligent Optical Link Mapper 41Customizing the Optical Power Meter2. Select the OPM tab.3. Select the power meter mode. The

Pagina 130

Setting User Preferences42 iOLMConfiguring your iOLMConfiguring your iOLMThe iOLM tab displays the settings used for taking measurements. The iOLM per

Pagina 131 - Adding Elements

Setting User Preferencesintelligent Optical Link Mapper 43Configuring your iOLMTo configure the iOLM:1. From the main window, select the iOLM tab.2. I

Pagina 132 - 126 iOLM

Contentsintelligent Optical Link Mapper v16 Warranty ...

Pagina 133

Setting User Preferences44 iOLMConfiguring your iOLM4. Specify if a launch and receive fibers are connected to the link under test, and enter their le

Pagina 134 - 128 iOLM

intelligent Optical Link Mapper 456 Managing Test ConfigurationsThis section explains the procedure to select, create, view and modify the test config

Pagina 135

Managing Test Configurations46 iOLMSelecting a Test ConfigurationTo select the test configuration:1. From the Main Menu, tap Test Config.2. Tap Select

Pagina 136 - 130 iOLM

Managing Test Configurationsintelligent Optical Link Mapper 47Selecting a Test Configuration3. Select the test configuration file.Note: If you have se

Pagina 137 - Deleting Elements

Managing Test Configurations48 iOLMImpacts of Test ConfigurationsImpacts of Test ConfigurationsBefore performing an acquisition, you can select or edi

Pagina 138 - Analyzing Links

Managing Test Configurationsintelligent Optical Link Mapper 49Creating a Test ConfigurationCreating a Test ConfigurationThe Duplicate button allows yo

Pagina 139

Managing Test Configurations50 iOLMCreating a Test Configuration2. Select Manage.3. Select the test configuration file to duplicate.4. Tap Duplicate.

Pagina 140 - Measurement Information

Managing Test Configurationsintelligent Optical Link Mapper 51Modifying a Test Configuration5. The default file name is displayed. You can modify the

Pagina 141

Managing Test Configurations52 iOLMModifying a Test ConfigurationModifying IdentifiersThe Identifiers tab allows you to view and modify the identifier

Pagina 142 - 136 iOLM

Managing Test Configurationsintelligent Optical Link Mapper 53Modifying a Test Configuration3. Select the test configuration file to modify. 4. Tap Mo

Pagina 143 - 13 Managing Files

Certification Informationvi iOLMCertification InformationNorth America Regulatory StatementThis unit was certified by an agency approved in both Canad

Pagina 144 - Opening iOLM Files

Managing Test Configurations54 iOLMModifying a Test Configuration6. Under Identifiers, select the identifiers from the list of available choices. Note

Pagina 145 - Saving iOLM Files

Managing Test Configurationsintelligent Optical Link Mapper 55Modifying a Test ConfigurationTo modify link definition:1. From the Main Menu, tap Test

Pagina 146 - 140 iOLM

Managing Test Configurations56 iOLMModifying a Test Configuration3. Select the test configuration file to modify. 4. Tap Modify.The name of the config

Pagina 147 - Managing Files

Managing Test Configurationsintelligent Optical Link Mapper 57Modifying a Test Configuration6. Select the split ratio of a splitter at a given stage.S

Pagina 148 - Exporting OTDR Bellcore Files

Managing Test Configurations58 iOLMModifying a Test Configuration7. Tap OK to save the changes and close the window, or tap Cancel to exit without sav

Pagina 149

Managing Test Configurationsintelligent Optical Link Mapper 59Modifying a Test ConfigurationEnabling 2:N Splitters (Optional, iOLM EXpert Mode Only)Th

Pagina 150 - 144 iOLM

Managing Test Configurations60 iOLMModifying a Test ConfigurationTo enable the 2:N splitter:1. From the Main Menu, tap Test Config > Manage.2. Sele

Pagina 151 - Generating a Report

Managing Test Configurationsintelligent Optical Link Mapper 61Modifying a Test Configuration4. Select the Link Definition tab from the test Configurat

Pagina 152 - 2. Tap Report

Managing Test Configurations62 iOLMModifying a Test ConfigurationThe element pass/fail status remains unknown in the following scenarios: If any elem

Pagina 153

Managing Test Configurationsintelligent Optical Link Mapper 63Modifying a Test ConfigurationManaging Custom Elements (Optional, iOLM EXpert Mode Only)

Pagina 154

intelligent Optical Link Mapper 11 Introducing the intelligent Optical Link MapperThe intelligent Optical Link Mapper (iOLM) is an optimized applicati

Pagina 155 - 14 Maintenance

Managing Test Configurations64 iOLMModifying a Test Configuration4. Tap Link Definition > Edit Custom Elements.5. Enter the custom element name und

Pagina 156 - Cleaning EUI Connectors

Managing Test Configurationsintelligent Optical Link Mapper 65Modifying a Test ConfigurationTo modify the custom element:1. From the Main Menu, select

Pagina 157 - IMPORTANT

Managing Test Configurations66 iOLMModifying a Test Configuration5. Select the custom element name under the Name column and modify it as needed.6. Se

Pagina 158 - Recalibrating the Unit

Managing Test Configurationsintelligent Optical Link Mapper 67Modifying a Test ConfigurationTo delete the custom element:1. From the Main Menu, select

Pagina 159 - Recycling and Disposal

Managing Test Configurations68 iOLMModifying a Test Configuration5. Tap the or icon (depending on the unit) beside the custom element which you wa

Pagina 160

Managing Test Configurationsintelligent Optical Link Mapper 69Modifying a Test ConfigurationModifying Link Pass/Fail ThresholdsThis tab allows you to

Pagina 161 - 15 Troubleshooting

Managing Test Configurations70 iOLMModifying a Test Configuration2. Select Manage.3. Select the test configuration file to modify. 4. Tap Modify.

Pagina 162 - 156 iOLM

Managing Test Configurationsintelligent Optical Link Mapper 71Modifying a Test Configuration5. Select the Link P/F Thresholds tab.6. Under Link P/F Th

Pagina 163 - From the Main Menu, tap

Managing Test Configurations72 iOLMModifying a Test Configuration7. Tap OK to save the changes and close the window, or tap Cancel to exit without sav

Pagina 164 - Transportation

Managing Test Configurationsintelligent Optical Link Mapper 73Modifying a Test Configuration2. Select Manage.3. Select the test configuration file to

Pagina 165 - 16 Warranty

Introducing the intelligent Optical Link Mapper2 iOLMOTDR port (singlemode)OTDR port (singlemode live and On-line power meter)Active LED(ON when laser

Pagina 166 - Liability

Managing Test Configurations74 iOLMModifying a Test Configuration5. Select the Element P/F Thresholds tab. The Threshold column displays the threshold

Pagina 167

Managing Test Configurationsintelligent Optical Link Mapper 75Modifying a Test Configuration6. Enable the Apply pass/fail option to access the paramet

Pagina 168 - Service and Repairs

Managing Test Configurations76 iOLMModifying a Test ConfigurationModifying Power Meter Pass/Fail ThresholdsThis tab allows you to modify the power met

Pagina 169

Managing Test Configurationsintelligent Optical Link Mapper 77Modifying a Test Configuration2. Select Manage.3. Select the test configuration file to

Pagina 170

Managing Test Configurations78 iOLMModifying a Test Configuration5. Select the OPM P/F Thresholds tab.6. Under OPM P/F Thresholds, modify the followin

Pagina 171 - A Technical Specifications

Managing Test Configurationsintelligent Optical Link Mapper 79Modifying a Test ConfigurationDeleting Test ConfigurationThe Delete button allows you to

Pagina 172 - FTB-720G

Managing Test Configurations80 iOLMModifying a Test Configuration2. Select Manage.3. Select the test configuration file to delete. 4. Tap Delete.A con

Pagina 173 - Technical Specifications

Managing Test Configurationsintelligent Optical Link Mapper 81Importing or Exporting a Test ConfigurationImporting or Exporting a Test ConfigurationTh

Pagina 174 - FTB-730G

Managing Test Configurations82 iOLMImporting or Exporting a Test Configuration2. Select Manage.3. Tap Import.

Pagina 175 - FTB-7300E

Managing Test Configurationsintelligent Optical Link Mapper 83Importing or Exporting a Test Configuration4. An Import dialog box opens, select the fil

Pagina 176 - FTB-7400E

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 3HandleVisual fault locator (VFL) port (optional)OTDR port (singlemode)

Pagina 177 - MAX-715B

Managing Test Configurations84 iOLMImporting or Exporting a Test ConfigurationTo export a test configuration:1. From the Main Menu, tap Test Config.2.

Pagina 178 - MAX-720B

Managing Test Configurationsintelligent Optical Link Mapper 85Importing or Exporting a Test Configuration3. Select the test configuration file. 4. Tap

Pagina 180

intelligent Optical Link Mapper 877 Starting an AcquisitionThis section explains the acquisition process of the iOLM.Starting an iOLM AcquisitionThis

Pagina 181

Starting an Acquisition88 iOLMStarting a Single-Wavelength AcquisitionStarting a Single-Wavelength AcquisitionThe single-wavelength acquisition allows

Pagina 182

Starting an Acquisitionintelligent Optical Link Mapper 89Starting a Single-Wavelength Acquisition2. Select the desired iOLM Wavelength(s) (one wavelen

Pagina 183

Starting an Acquisition90 iOLMStarting a Multiple-Wavelength AcquisitionStarting a Multiple-Wavelength AcquisitionThe multiple-wavelength acquisition

Pagina 184 - ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩

Starting an Acquisitionintelligent Optical Link Mapper 91Starting a Multiple-Wavelength Acquisition2. Select the desired iOLM Wavelength(s).3. Tap Sta

Pagina 185 - MARKING REQUIREMENTS

Starting an Acquisition92 iOLMStopping an AcquisitionStopping an AcquisitionThe acquisition stops automatically after the acquisition is complete.It i

Pagina 186

intelligent Optical Link Mapper 938 Understanding DiagnosticsThis section explains the diagnostics feature available in the iOLM application. Diagnost

Comentarios a estos manuales