Ethernet and Fibre Channel Application 395
Ping Configuration
Delay (ms): Available for ping only. Enter the delay between each
attempt (PING). Choices are 100 to 10000 ms. The default setting is
1000 ms.
Data Size (Bytes): Available for ping only. Enter the buffer size that will
be sent to the network device to be detected. Choices are 0 to 1472
bytes. Default value is 32 bytes.
Time To Live (TTL) for IPv4
Hop Limit (TTL) for IPv6
Enter the maximum number of hops the packet can go through.
Choices are 1 to 255. The default setting is 128.
Flow Label (IPv6 only): Enter the Flow Label number that will be used
to identify a series of related packets from a source to a destination.
Choices are 0 to 1048575. The default setting is 0.
Attempts and Continuous: Enter the number of attempt that will be
performed to reach the network device or press Continuous to
attempt indefinitely. Choices are 1 to 100. The default setting is 4 and
Continuous is disabled.
Type Of Service (TOS) for IPv4
Traffic Class (TOS) for IPv6
Enter the type of service. Choices are 00 to FF. The default setting is 00.
Binary: Enable binary to set the TOS field in binary mode. Otherwise,
the TOS field is in hexadecimal mode. This setting is disabled by
default.