Creating and Starting a Test Case
112 FTB-8500 Series and FTB-8120NGE/8130NGE
Ethernet TCP Throughput Test Case
2. Port configuration:
Port 1 (FTB-8510B only) is automatically selected.
2a. Select the port Connector
Type (Optical or
Electrical RJ-45). Optical is automatically selected for the
Ethernet 10G interface.
2b. For Electrical RJ-45, if required, select
the Ethernet port crossover check box
to inverse the pin-to-pair assignment of
the UTP cable used.
Note: At this point you should have a link up indicated in the Tr ee view tab. A
green LED indicates a link up while a red LED indicates a link down. For
electrical port, if the link is down, make sure that the Ethernet port
crossover setting is correct.
2c. Press Next.
3. Framing configuration:
3a. Set the Auto-Negotiation, Speed,
Duplex, and Flow Control parameters.
Refer to Interface Setup (Ethernet) on
page 140 for more information.
3b. Select the Frame Format. Choices are
Ethernet II and 802.3 SNAP. Refer to
Network on page 148 for more
information.
3c. Set the IP Address (IPv4), Automatic IP
address, Subnet Mask, and Default
Gateway parameters. Refer to Source IP Configuration on
page 150 for more information.
3d. Press Finish to complete the test setup. The Alarm summary tab
is automatically displayed.