User GuideChromatic Dispersion Analyzer for FTB-500FTB-5800

Pagina 2

Introducing the FTB-5800 Chromatic Dispersion Analyzer4 FTB-5800ConventionsConventionsBefore using the product described in this manual, you should un

Pagina 3 - Contents

Measuring Chromatic Dispersion: Theory92 FTB-5800Using Data Fits to Obtain DispersionUsing Data Fits to Obtain DispersionThis section gives you detail

Pagina 4

Measuring Chromatic Dispersion: TheoryChromatic Dispersion Analyzer 93Using Data Fits to Obtain DispersionAs the previous table demonstrates, specific

Pagina 5 - Certification Information

Measuring Chromatic Dispersion: Theory94 FTB-5800Helping You Manage Chromatic DispersionHelping You Manage Chromatic DispersionThe zero-dispersion wav

Pagina 6 - DECLARATION OF CONFORMITY

IndexChromatic Dispersion Analyzer 95IndexAaccessing File Export ... 65accuracy, results...

Pagina 7 - 1 Introducing the FTB-5800

Index96 FTB-5800exiting application... 12, 65exportingchromatic dispersion files ... 65results...

Pagina 8 - Main Features

IndexChromatic Dispersion Analyzer 97printingarranging report presentation ... 62setup parameters... 63pro

Pagina 9 - Typical Applications

Index98 FTB-5800traces, acquiring many ... 35transportation requirements ... 71, 81Uunit recalibration...

Pagina 10 - IMPORTANT

NOTICE通告CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES中国关于危害物质限制的规定NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Pagina 11 - 2 Getting Started with Your

MARKING REQUIREMENTS标注要求Product产品Environmental protection use period (years)环境保护使用期限 ( 年 )Logo标志This Exfo product本 EXFO 产品10Batterya电池aa. If applicabl

Pagina 12 - 6 FTB-5800

www.EXFO.com · [email protected]/N: 1055210CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Pagina 13 - FTB-500 left panel

Chromatic Dispersion Analyzer 52 Getting Started with Your Chromatic Dispersion AnalyzerInserting and Removing Test ModulesTo insert a module into the

Pagina 14 - 8 FTB-5800

Getting Started with Your Chromatic Dispersion Analyzer6 FTB-5800Inserting and Removing Test Modules3. Take the module and place it so that the connec

Pagina 15

Getting Started with Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 7Inserting and Removing Test Modules7. While applying slight pres

Pagina 16 - Application

Getting Started with Your Chromatic Dispersion Analyzer8 FTB-5800Inserting and Removing Test ModulesTo remove a module from the FTB-500 Universal Test

Pagina 17

Getting Started with Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 9Inserting and Removing Test Modules5. Hold the module by its sid

Pagina 18 - Exiting the Application

Getting Started with Your Chromatic Dispersion Analyzer10 FTB-5800Starting the Chromatic Dispersion Analyzer ApplicationStarting the Chromatic Dispers

Pagina 19 - Dispersion Analyzer

Getting Started with Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 11Starting the Chromatic Dispersion Analyzer ApplicationThe main

Pagina 20 - Setting the Wavelength Step

Getting Started with Your Chromatic Dispersion Analyzer12 FTB-5800Exiting the ApplicationStatus BarThe status bar, located at the bottom of the main w

Pagina 21

Chromatic Dispersion Analyzer 133 Setting Up Your Chromatic Dispersion AnalyzerThe parameters you set will be kept in memory after turning off the FTB

Pagina 22 - Setting the Averaging Time

ii FTB-5800Copyright © 2002–2009 EXFO Electro-Optical Engineering Inc. All rights reserved. No part of this publication may be reproduced, stored in a

Pagina 23

Setting Up Your Chromatic Dispersion Analyzer14 FTB-5800Setting the Wavelength StepSetting the Wavelength StepThe wavelength step corresponds to the i

Pagina 24 - 18 FTB-5800

Setting Up Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 15Setting the Wavelength StepTo set the wavelength step using the custom op

Pagina 25

Setting Up Your Chromatic Dispersion Analyzer16 FTB-5800Setting the Averaging TimeSetting the Averaging TimeThe averaging time is the time the system

Pagina 26 - 20 FTB-5800

Setting Up Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 17Specifying the Fiber Under TestSpecifying the Fiber Under TestBefore maki

Pagina 27

Setting Up Your Chromatic Dispersion Analyzer18 FTB-5800Specifying the Fiber Under TestTo specify the fiber under test: In the Parameters tab, undr Fi

Pagina 28

Setting Up Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 19Specifying the Fiber Under TestTo modify the distance units:1. On the but

Pagina 29 - 4 Operating Your Chromatic

Setting Up Your Chromatic Dispersion Analyzer20 FTB-5800Defining the Automatic Fiber Name FormatDefining the Automatic Fiber Name FormatEach time you

Pagina 30

Setting Up Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 21Defining the Automatic Fiber Name FormatTo define the fiber name format:1

Pagina 32 - Selecting the Source Type

Chromatic Dispersion Analyzer 234 Operating Your Chromatic Dispersion AnalyzerInstalling the EXFO Universal Interface (EUI)The EUI fixed baseplate is

Pagina 33

ContentsChromatic Dispersion Analyzer iiiContentsCertification Information ...

Pagina 34

Operating Your Chromatic Dispersion Analyzer24 FTB-5800Cleaning and Connecting Optical FibersCleaning and Connecting Optical FibersTo connect the fibe

Pagina 35

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 25Cleaning and Connecting Optical Fibers3. Carefully align the connector and

Pagina 36 - 30 FTB-5800

Operating Your Chromatic Dispersion Analyzer26 FTB-5800Selecting the Source TypeSelecting the Source TypeDifferent sources can be used for testing wit

Pagina 37

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 27Verifying the Intensity of the SourceVerifying the Intensity of the Source

Pagina 38 - 32 FTB-5800

Operating Your Chromatic Dispersion Analyzer28 FTB-5800Performing Reference MeasurementsPerforming Reference MeasurementsIMPORTANTTo ensure the best p

Pagina 39

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 29Performing Reference MeasurementsReference typeRecommended reference frequ

Pagina 40

Operating Your Chromatic Dispersion Analyzer30 FTB-5800Performing Reference MeasurementsTo take a wavelength reference:Note: If the application has pr

Pagina 41 - Creating a File

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 31Performing Reference Measurements3. On the Wavelength tab, select the sour

Pagina 42

Operating Your Chromatic Dispersion Analyzer32 FTB-5800Performing Reference MeasurementsTo take a chromatic dispersion reference:1. Ensure that a wave

Pagina 43

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 33Performing Reference Measurements4. On the CD tab, identify the source fro

Pagina 44 - 38 FTB-5800

Contentsiv FTB-58006 Exporting CD Analyzer Files with the File Export Tool ...65Starting and Exiting the File Export Tool

Pagina 45

Operating Your Chromatic Dispersion Analyzer34 FTB-5800Applying a Chromatic Dispersion ReferenceApplying a Chromatic Dispersion ReferenceChromatic dis

Pagina 46 - Saving Your Results

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 35Creating a FileCreating a FileEach time you make an acquisition, the resul

Pagina 47 - 5 Managing Results

Operating Your Chromatic Dispersion Analyzer36 FTB-5800Measuring Chromatic DispersionMeasuring Chromatic DispersionYou can perform both single and mul

Pagina 48 - Recalling a Saved File

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 37Measuring Chromatic Dispersion4. Set the parameters.³ Single acquisition:

Pagina 49

Operating Your Chromatic Dispersion Analyzer38 FTB-5800Measuring Chromatic Dispersion7. On the button bar, click Start.The Start button becomes a red

Pagina 50 - 44 FTB-5800

Operating Your Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 39Saving Your ResultsSaving Your ResultsOnce your acquisition is done, you m

Pagina 51

Operating Your Chromatic Dispersion Analyzer40 FTB-5800Saving Your Results2. Select the folder in which you want to save your data or create a folder

Pagina 52 - 46 FTB-5800

Chromatic Dispersion Analyzer 415 Managing ResultsYour FTB-5800 Chromatic Dispersion Analyzer allows you to work with two types of results:³ Newly acq

Pagina 53 - Managing Results

Managing Results42 FTB-5800Recalling a Saved FileRecalling a Saved FileIt is possible to reload existing files in .exfocd format. These files can also

Pagina 54 - 48 FTB-5800

Managing ResultsChromatic Dispersion Analyzer 43Analyzing Results from the Results GraphAnalyzing Results from the Results GraphThe application presen

Pagina 55

Certification InformationChromatic Dispersion Analyzer vCertification InformationF.C.C. InformationElectronic test equipment is exempt from Part 15 co

Pagina 56

Managing Results44 FTB-5800Analyzing Results from the Results GraphEven if you have acquired your results with a particular type of data fitting, duri

Pagina 57

Managing ResultsChromatic Dispersion Analyzer 45Analyzing Results from the Results GraphTo show or hide the fitted lambda zero value:1. On the button

Pagina 58

Managing Results46 FTB-5800Analyzing Results from the Results GraphTo show or hide the RGD curves and/or RGD values1. On the button bar, click Setup.2

Pagina 59

Managing ResultsChromatic Dispersion Analyzer 47Analyzing Results from the Results GraphTo interpret results using a different type of fit:On the Resu

Pagina 60 - Keeping Track of Acquisitions

Managing Results48 FTB-5800Analyzing Results from the Results GraphTo position the marker:³ Drag the marker to the point you want to focus on.³ Use th

Pagina 61

Managing ResultsChromatic Dispersion Analyzer 49Analyzing Results from the Results GraphTo zoom in on results or zoom out:1. On the Results Graph tab,

Pagina 62 - Establishing Thresholds

Managing Results50 FTB-5800Analyzing Results from the Results GraphTo revert the zoom factor to its default value:1. On the Results Graph tab, click t

Pagina 63

Managing ResultsChromatic Dispersion Analyzer 51Analyzing Results from the Results GraphTo have the zoom reset automatically:1. On the button bar, cli

Pagina 64 - 58 FTB-5800

Managing Results52 FTB-5800Analyzing Results from the Results TableAnalyzing Results from the Results TableThe columns presented on the Results Table

Pagina 65 - Documenting Results

Managing ResultsChromatic Dispersion Analyzer 53Analyzing Results from the Results TableWhen applicable, in the dispersion and coefficient of dispersi

Pagina 66 - 60 FTB-5800

Certification Informationvi FTB-5800 Application of Council Directive(s): 2006/95/EC - The Low Voltage Directive 2004/108/EC - The EMC Directive

Pagina 67

Managing Results54 FTB-5800Keeping Track of AcquisitionsTo select or deselect points:Select or deselect the corresponding boxes in the first column of

Pagina 68 - Printing Results

Managing ResultsChromatic Dispersion Analyzer 55Keeping Track of AcquisitionsTo display an overall view of the results:Click the Acquisitions tab.To d

Pagina 69

Managing Results56 FTB-5800Establishing ThresholdsEstablishing ThresholdsYou can establish two types of thresholds: the dispersion and slope 0 thresho

Pagina 70

Managing ResultsChromatic Dispersion Analyzer 57Establishing ThresholdsThe Slope 0 Threshold is the slope of the dispersion curve evaluated at the poi

Pagina 71 - ³ text files

Managing Results58 FTB-5800Establishing ThresholdsTo establish your thresholds:1. On the button bar, click Setup.2. Set the thresholds as required.³ I

Pagina 72 - To exit the export tool:

Managing ResultsChromatic Dispersion Analyzer 59Documenting ResultsDocumenting ResultsFor easier management, you may want to add comments and informat

Pagina 73 - Setting Export Parameters

Managing Results60 FTB-5800Documenting ResultsTo add specific information:1. On the Acquisitions tab, select the acquisition you wish to comment (the

Pagina 74 - Export Tool on page 65)

Managing ResultsChromatic Dispersion Analyzer 61Exporting Results and Graphs to ClipboardExporting Results and Graphs to ClipboardThe FTB-5800 Chromat

Pagina 75

Managing Results62 FTB-5800Printing ResultsPrinting ResultsThe Chromatic Dispersion Analyzer allows you to print reports containing test information a

Pagina 76

Managing ResultsChromatic Dispersion Analyzer 63Printing Results4. Select Print All Acquisitions or Print Current Acquisition Only, depending on the t

Pagina 77 - Unsuccessful

Chromatic Dispersion Analyzer 11 Introducing the FTB-5800 Chromatic Dispersion AnalyzerIn today’s advanced optical network, chromatic dispersion manag

Pagina 79 - 7 Maintenance

Chromatic Dispersion Analyzer 656 Exporting CD Analyzer Files with the File Export ToolThe File Export tool has been designed to export chromatic disp

Pagina 80

Exporting CD Analyzer Files with the File Export Tool66 FTB-5800Starting and Exiting the File Export ToolThe File Export tool main window is displayed

Pagina 81

Exporting CD Analyzer Files with the File Export ToolChromatic Dispersion Analyzer 67Setting Export ParametersSetting Export ParametersBefore exportin

Pagina 82 - Recalibrating the Unit

Exporting CD Analyzer Files with the File Export Tool68 FTB-5800Setting Export ParametersTo set export parameters:1. If necessary, open the File Expor

Pagina 83 - Recycling and Disposal

Exporting CD Analyzer Files with the File Export ToolChromatic Dispersion Analyzer 69Setting Export Parameters3. On the Settings function tab, select

Pagina 84

Exporting CD Analyzer Files with the File Export Tool70 FTB-5800Exporting Chromatic Dispersion FilesExporting Chromatic Dispersion FilesOnce the expor

Pagina 85 - 8 Troubleshooting

Exporting CD Analyzer Files with the File Export ToolChromatic Dispersion Analyzer 71Exporting Chromatic Dispersion Files4. Select the files.4a. Under

Pagina 87 - Viewing Online Documentation

Chromatic Dispersion Analyzer 717 MaintenanceTo help ensure long, trouble-free operation:³ Always inspect fiber-optic connectors before using them and

Pagina 88 - FTB-5800-XX

Introducing the FTB-5800 Chromatic Dispersion Analyzer2 FTB-5800Main FeaturesThe architecture of the FTB-5800 Chromatic Dispersion Analyzer places the

Pagina 89 - Transportation

Maintenance72 FTB-5800Cleaning EUI ConnectorsCleaning EUI ConnectorsRegular cleaning of EUI connectors will help maintain optimum performance. There i

Pagina 90

MaintenanceChromatic Dispersion Analyzer 73Cleaning EUI Connectors5. Repeat steps 3 to 4 with a dry cleaning tip.Note: Make sure you don’t touch the s

Pagina 91 - 9 Warranty

Maintenance74 FTB-5800Recalibrating the UnitRecalibrating the UnitManufacturing and service center calibrations are based on the ISO/IEC 17025 Standar

Pagina 92 - Liability

MaintenanceChromatic Dispersion Analyzer 75Recycling and Disposal (Applies to European Union Only)Recycling and Disposal (Applies to European Union On

Pagina 94 - Service and Repairs

Chromatic Dispersion Analyzer 778 TroubleshootingSolving Common ProblemsFatal Error Consequences Recommended SolutionModule temperature is too high fo

Pagina 95

Troubleshooting78 FTB-5800Solving Common ProblemsWarning Consequences Recommended SolutionSource power is low. Some points will be grayed out on the g

Pagina 96

TroubleshootingChromatic Dispersion Analyzer 79Viewing Online DocumentationViewing Online DocumentationAn online version of the FTB-5800 Chromatic Dis

Pagina 97 - A Technical Specifications

Troubleshooting80 FTB-5800Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technical suppo

Pagina 98

TroubleshootingChromatic Dispersion Analyzer 81TransportationTransportationMaintain a temperature range within specifications when transporting the un

Pagina 99 - Dispersion: Theory

Introducing the FTB-5800 Chromatic Dispersion AnalyzerChromatic Dispersion Analyzer 3Basic TheoryBasic TheoryChromatic dispersion is the natural broad

Pagina 101

Chromatic Dispersion Analyzer 839 WarrantyGeneral InformationEXFO Electro-Optical Engineering Inc. (EXFO) warrants this equipment against defects in m

Pagina 102 - 94 FTB-5800

Warranty84 FTB-5800LiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any fail

Pagina 103

WarrantyChromatic Dispersion Analyzer 85ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its produc

Pagina 104

Warranty86 FTB-5800Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the date of pur

Pagina 105

WarrantyChromatic Dispersion Analyzer 87EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your n

Pagina 107 - 中国关于危害物质限制的规定

Chromatic Dispersion Analyzer 89A Technical SpecificationsIMPORTANTThe following technical specifications can change without notice. The information p

Pagina 109

Chromatic Dispersion Analyzer 91B Measuring Chromatic Dispersion: TheoryEXFO’s Chromatic Dispersion Analyzer applies the phase-shift method, which con