Configuring and Starting a Test
58 ETS-1000
RFC 2544. Performing Analysis
The diagram shows throughput values for each specified frame size. The
measured throughput value in Frm/s and in percentage (relatively to the
specified rate) is displayed on the diagram vertical bars.
The results may be displayed in two ways (press button):
1. The maximum value marked on the Y axis is the maximum
transmission rate value. The X axis shows frame size value. Empty bars
display maximum theoretical rate value. Completed bars display
measured rate value.
2. The maximum value marked on the Y axis is the maximum measured
rate value. The X axis shows frame size value.